A Refrigerator Uses Refrigerant-134a as the Working Fluid
A refrigerator uses refrigerant-134a as the working fluid and operates on the vapor-compression refrigeration cycle. The isentropic efficiency of the compressor is 88 percent.
Solved A Refrigerator Uses Refrigerant 134a As The Working Chegg Com
A refrigerator uses refrigerant-134a as the working fluid and operates on the vapor-compression refrigeration cycle.
. The refrigerant enters the compressor at a rate of 0025 kgs superheated by. A refrigerator uses refrigerant-134a as the working fluid and operates on the ideal vapor-compression refrigeration cycle except for the compression process. Show the cycle on a T-s diagram with respect to.
The isentropic efficiency of the compressor is 88 percent. The refrigerant enters the evaporator at 120 kPa with a quality of 34 percent and leaves the compressor at 70circ C. This unit serves a 45000 Btuh cooling load.
A commercial refrigerator with refrigerant-134a as the working fluid is used to A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -30C by rejecting its waste heat to cooling water that enters the condenser at 18C at a rate of 025 kgs and leaves at 26C. A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at 2300C by rejecting its waste heat to cooling water that enters the condenser at 180C at a rate of 025 kgs and leaves at 260C. A refrigerator uses R-134a as its refrigerant and operates on an ideal vapour-compression refrigeration cycle between 014 MPa and 08 MPa.
The evaporator and condenser pressures are 200 kPa and 1400 kPa respectively. The refrigerant enters the condenser at 12 MPa and 650C and leaves at 420C. Thermodynamics 7th Edition Edit edition Solutions for Chapter 11 Problem 23P.
The evaporator and condenser pressures are 200 kPa and 1400 kPa respectively. The isentropic efficiency of the compressor is 88 percent. If the mass flow rate of the refrigerant is 005 kgs the rate of heat rejection to the environment is _____ kW.
A refrigerator uses refrigerant-134a as the working fluid and operates on the vapor-compression refrigeration cycle. A refrigerator uses refrigerant-134a as the working fluid and operates on the vapor- compression refrigeration cycle. A refrigerator uses refrigerant-134a as the working fluid and operates on an ideal vapor-compression refrigeration cycle between 024 and 07 MPa.
If the compressor consumes 450 W of power determine. The refrigerant enters the evaporator at 120 kPa with a quality of 30 percent and leaves the compressor at 60C. The refrigerant enters the evaporator at 120 kPa with a quality of 34 percent and leaves the compressor at 70C.
Determine the mass flow rate of the refrigerant and the power that this unit will require. The refrigerant enters the evaporator at 120 kPa with a quality of 30 percent and leaves the compressor at 60C. A refrigerator uses refrigerant-134a as the working fluid and operates on the vapor-compression refrigeration cycle.
The evaporator and condenser pressures are 200 kPa and 1400 kPa respectively. Find step-by-step Engineering solutions and your answer to the following textbook question. The Ideal Vapor-Compression Refrigeration Cycle A refrigerator uses refrigerant-134a as the working fluid and operates on an ideal vapor-compression refrigeration cycle between 014 and 08 MPa.
The refrigerant evaporates at 5F and condenses at 180 psia. At P 014 MPa h 23604 kJkg s 09322 kJkg-K. C The net work input.
The refrigerant enters the evaporator at 120 kPa with a quality of 34 percent and leaves the compressor at 70oC. Once an answer is submitted you will be unable to return to this part A refrigerator uses refrigerant-134a as the working fluid and follows the ideal vapor-compression refrigeration cycle with a non isentropic compressor. The refrigerant enters the evaporator at 120 kPa with a quality of 30 percent and leaves the compressor at 60C and 060 MPa pressure.
A refrigerator uses refrigerant-134a as the working fluid and operates on the ideal vapor-compression refrigeration cycle except for the compression process. The mass flow rate of. A refrigerator uses refrigerant-134a as the working fluid and operates on the ideal vapor-compression refrigeration cycle except for the compression process.
A refrigerator uses refrigerant-134a as the working fluid and operates on the ideal vapor-compression refrigeration cycle except for the compression process. A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -35C by rejecting waste heat to cooling water that enters the condenser at 18C at a rate of 025 kgs and leaves at 26C. The refrigerant enters the evaporator at 120 kPa with a quality of 34 percent and leaves the compressor at 70C.
If the compressor consumes 450 W of power determine a The mass flow rate of the refrigerant. The isentropic efficiency of the compressor is 88 percent. 2 A refrigerator uses refrigerant-134a as the working fluid and operates on an ideal vapor-compression refrigeration cycle between 012 and 07 MPa.
The evaporator and condenser pressures are 200 kPa and 1400 kPa respectively. The isentropic efficiency of the compressor is 88 percent. A refrigerator uses refrigerant-134a as its working fluid and operates on the ideal vapor-compression refrigeration cycle.
A refrigerator uses refrigerant-134a as the working fluid and operates on the ideal vapor-compression refrigeration cycle. If the compressor consumes 450 W of power determine. The evaporator and condenser pressures are 200 mathrmkPa and 1400 mathrmkPa respectively.
The mass flow rate of the refrigerant is 005 kgs. The evaporator and condenser pressures are 200 kPa and 1400 kPa respectively. A refrigerator uses refrigerant-134a as the working fluid and operates on the vapor-compression refrigeration cycle.
A refrigerator uses refrigerant-134a as the working fluid and operates on the ideal vapor-compression refrigeration cycle. The refrigerant enters the condenser at 12 MPa and 50C and leaves at the same pressure subcooled by 5C. The isentropic efficiency of the compressor is 88 percent.
Solved A Commercial Refrigerator With Refrigerant 134a As Chegg Com
A Refrigerator With Refrigerant 134a As The Working Fluid Is Considered Me470 Refrigeration Cycles Hw Solutions Inst Chapter 11 Solution 18
Solved 11 21 A Refrigerator Uses Refrigerant 134a As The Chegg Com
Solved A Refrigerator Uses Refrigerant 134a As The Working Chegg Com
0 Response to "A Refrigerator Uses Refrigerant-134a as the Working Fluid"
Post a Comment